雷竞技appFluke correction 9102 portable dry type furnace

The main function

World's smallest, lightest and most portable dry - Wells

  • The Smallest dry - Wells in the world
  • Ranges from - 10 ° C to 122 ° C
  • Accuracy to + / - 0.25 ° C, stability of + / - 0.05 ° C
  • The RS - 232 interface
  • 雷竞技appFluke Calibration 's line of portable dry - Wells is incredible. They' re the smallest, lightest, and most portable dry - Wells in the world. And now They 'r e better than (!

Produc雷竞技appts overview: Fluke correction 9102 portable dry type furnace

9102 s Dry - Well

For the work in the temperature range of - 10 ° C to 122 ° C, 9102 s dry - well is another first in the industry, featuring stability to + / - 0.05 ° C.

This dry - well is only four inches high and six inches wide, achieves temperatures as low as 10 ° C, includes a NIST - traceable calibration, and is stable to + / - 0.05 ° c. The Model 9102 s is excellent for dial gauges, digital thermometers, bulbs, switches, and other sensors that need calibration below ambient.

The 9102 s has two Wells so you can use one for a reference thermometer to happens accuracy. Both Wells are 1/2 inch in diameter, and each has inserts available for almost any sensor size. The 9102 s also has a 'pack option that gives you approximately four hours of field use The when AC power is unavailable.

Spec雷竞技appification: Fluke correction 9102 portable dry type furnace

Specifications

9100 s 9102 s
The Range
35 ° C to 375 ° C (95 ° F to 707 ° F)
- 10 ° C to 122 ° C (14 ° F to 252 ° F) at23 ° C ambient
Accuracy
+ / - 0.25 ° C at 50 ° C;+ / - 0.25 ° C at 100 ° C;+ / - 0.5 ° C at 375 ° C + / - 0.25 ° C
Stability
+ / - 0.07 ° C at 50 ° C;+ / - 0.1 ° C at 100 ° C;+ / - 0.3 ° C at 375 ° C + / - 0.05 ° C
Well - to - Well Uniformity + / - 0.2 ° C with sensors of similar size at equal depths within Wells
Heating Times 35 ° C to 375 ° C: 9.5 minutes Ambient to 100 ° C: 10 minutes
Stabilization 5 minutes 7 minutes
Cooling Times 375 ° C to 100 ° C: 14 minutes Ambient to 0 ° C: 10 minutes
Well the Depth
102 mm (4 in);1.6 mm (1/16) in the hole is 89 mm (3.5 in) deep 102 mm (4) in
Removable Inserts


N/A


Available in sizes from 1.6 mm to 11.1 mm (1/16 in) (7/16) in [(1/4) in 6.4 mm and 4.8 mm (3/16) in the included]
The Power
115 V ac (+ / - 10%), 55-65 Hz, 1.5 A or 230 V ac (+ / - 10%), 0.8 A, 45-55 Hz, 175 W 94-234 - V ac (+ / - 10%), 50/60 Hz, 60 W;Or 12 VDC
The Size (HxWxD)
57 x 125 x 150 mm (2.25 x 4.9 x 6.1 in) 99 x 140 x 175 mm (3.9 x 5.5 x 6.9 in)
Weight 1 kg (2 lb 3 oz) 1.8 kg (4 lb)
Computer Interface The RS - 232 included
NIST - TraceableCalibration

Data at 50 ° C to 100 ° C to 150 ° C to 200 ° C to 250 ° C to 300 ° C, and 375 ° C Data at - 10 ° C, 0 ° C, 25 ° C, 50 ° C and 75 ° C and 100 ° C, and 122 ° C

Mode雷竞技appl: Fluke correction 9102 portable dry type furnace

9102 s

9102 s - 156, DRY - WELL, HH LOW TEMP

buy

HDRC Handheld Dry - Well