雷竞技appFluke 1524 reference thermometer

The main function

Accurate and stable measurement anytime and anywhere.
In order to ensure compliance, to gain excellent yield, excellent energy saving effect and stable and consistent results, you need accurate measurement.In 1524 adopted the only high-end instrument to use the power of backward technology, eliminates the thermoelectric emfs (EMF), thus can realize accurate temperature measurement.According to the design specification, it can be - DHS 10 to 60 C DHS C environment normal work.Special precision resistance and high stability of the reference voltage source can make 1524 almost not affected by the external environment temperature.

Like al雷竞技appl other handheld tools Fluke, 1524 reference thermometer in extreme temperatures, and the vibration of the harsh conditions after a rigorous testing.

Therefore, the user can take it to any where it is needed.Optional magnetic suspension device allows the user to hang the thermometer, not only easy to see, still can make his hands to focus on work.

The INFO - CON connectors to ensure the correct temperature conversion
INFO - CON joint built-in memory chips contain information used to connect the probe calibration.Simply insert the probe, and the calibration information can be uploaded to the reader, to ensure that the correct temperature conversion, so as to realize the measurement of accurate without interference.

For safety or the traceability system calibration, user can set the password to the probe locked to a specific channel and reader.User can insert the thermocouple with a mini plug optional general thermocouple adapter, convenient measurement.Each thermocouple adapter or standard joint through internal precision thermistor support thermocouple cold junction compensation (RJC).

In the laboratory or field monitoring trends
In 1524 128 x64 LCD backlit thermometer see trends in graphics.In addition, just touch of a button can change the resolution of the graphics.Now, you can easily view during temperature stabilized (without statistics or long time delay), and monitor process over a period of time to verify whether it is right to operate.

According to the need to record up to 25 pairs of readings and related statistical data, convenient retrieval.The user can view the data from your screen, also can through the RS - 232 interface to upload to PC with 9940 software (free attached) to see.In a period of time to monitor and record more data, please use PC and optional LogWareII software.

For users like to use the USB connector, also can use the provided by RS - 232 / USB adapter.Using three AA batteries, battery can last for at least 20 hours, also can use dc power adapter in order to realize the measurement for a longer time.In order to achieve a longer battery life or more convenience, the user can enable or disable the power saving function.

Two models for choice
1523 reference thermometer is a multifunctional single channel thermometer, let users through a tool can measure three types of sensors, drawing, and records.Due to the support of PRT/RTD, thermocouple and thermistor, so users can correct probe flexibility to choose suitable for their work.

The new 1524 reference meter allows users to use double the work completed in half the time.Two channels, three kinds of sensor types and high speed measurement allows the user to work more efficiently, makes 1524 users a kind of essential reference thermometer.It has all the features of 1523, at the same time, it is also a data recorder.Real time clock and the date and time can record 15000 times of measurement means that this kit provides everything you need for a user.Record frequency can be three times per second, one hour at a time, or between the two options.When necessary, can also download the data to PC for analysis.

application
1524 thermometer USES is very wide, and some application examples including calibration, loop check, workshop start test, troubleshooting, maintenance, repair and so on.Using it, the user can in the bathroom, dry postures temperature calibration instrument, the thermometer casing, clean room, engine, heat exchanger, furnace, freezer, or any other places need calibration, inspection or maintenance convenient temperature measurement.

Produc雷竞技appts overview: Fluke 1524 reference thermometer

Use a tool to measure, mapping and record three types of sensors

雷竞技appFluke subsidiary Hart Scientific Division launched 1524 reference thermometer can measure, drawing and document PRT, thermocouple and thermistor.The thermometer readings have excellent precision, wide range, recording and trend of drawing function, all of this are completed by a portable hand-held tool.
1523 allows you to easily cope with field application, laboratory measurement and data records.In addition, with the 1524 model of dual channel measurement functions, users can also use a double work completed in half the time.

Three types of sensors

  • PRT: - 200 ° C to 1000 ° C
  • Thermocouple: - 200 ° C to 2315 ° C
  • Precision thermistor: - 50 ° C to 150 ° C
  • PRT: up to + / - 0.011 ° C
  • Thermocouple: + / - 0.24 ° C, suitable for J, K, L and M type
  • Precision thermistor: + / - 0.002 ° C
  • PRT: sampling 0.45 seconds at a time
  • Thermocouple: sampling 0.3 seconds at a time
  • Precision thermistor: sampling 0.3 seconds at a time
  • 1524: dual channel;Measurement of memory can record 15000 times;Mark the real time clock is used to display the date and time

Graphical display

  • 128 x64 LCD backlit graphical display
  • Real-time graphics and trends
  • Synchronous dual channel readings

Spec雷竞技appification: Fluke 1524 reference thermometer

Specifications
The Input Channels
1523:1.
1524-2
Logging
1523:25 readings with statistics
1524-15000 time and date stamped;25 readings with statistics
The Sample interval
(normal)
1 seconds
The Sample interval (fast mode)
0.3 seconds (see technical manual for details)
Sensor Types
PRTs, RTDs, Thermistors and Thermocouples
Thermocouple Types
C, E, J, K, L, M, N, T, U, B, R, S
Operating temperature
- 10 DHS to 60 C DHS C (Best accuracy DHS 13 C to DHS C 33)
The Power requirements
3 AA alkaline batteries
The Size
96 x 200 x 47 mm
(3.75 x 7.9 x 1.86 inches)
Weight
0.65 kg (1.4 lb)
Environmental the conditions for best accuracy
13 ° C to 33 ° C
Millivolt Range and Accuracy
- 10 mV to mV - 75 mu (0.005% + 5 V)
To hold the Range and Accuracy
0 Ω to 400 Ω plus or minus 0.002 Ω (+ 0.004%)
200 Ω to 50 k Ω plus or minus 0.5 Ω (+ 0.01%)
Ω Ω 50 k to 500 k + (0.03%)
Temperature Coefficient, Voltage (-- 10 ° C to 13 ° C and + 33 ° to 60 ° C) C
Plus or minus 0.001% (/ ° C + 1 mu V / ° C)
Temperature Coefficient, hold (-- 10 ° C to 13 ° C and + 33 ° to 60 ° C) C
0.0008% / + 0.0004 ° C Ω Ω (0 to 400 Ω)
0.002% / + 0.1 ° C Ω Ω (0 to 50 k Ω)
0.06% / + 0.1 ° C Ω Ω Ω (50 k to 500 k)
Excitation Current, to hold
1 mA Ω (0 to 400 Ω)
10 mu A Ω (0 to 50 k Ω)
2 (including A Ω Ω (50 k to 500 k)
Thermocouple equivalent temperature accuracies (readout only)
Type B
+ / - 0.85 C from DHS 600 DHS to 800 DHS C C
+ / - 0.68 C from DHS 800 DHS to 1000 DHS C C
+ / - 0.57 C from DHS 1000 DHS to 1800 DHS C C
Type C
+ / - 0.32 C from DHS 100 DHS to 550 DHS C C
+ / - 0.71 C from DHS 550 DHS to 2300 DHS C C
Type E
DHS C from 0.52 mm - 200 DHS DHS to 0 C C
+ / - 0.22 DHS DHS from 0 to 950 DHS C C C
Type J
DHS C from 0.52 mm - 200 DHS DHS to 0 C C
+ / - 0.23 DHS DHS from 0 to 1200 DHS C C C
Type K.
DHS C from 0.61 mm - 200 DHS DHS to 0 C C
+ / - 0.24 DHS DHS from 0 to 1370 DHS C C C
The Type of L
DHS C from 0.36 mm - 200 DHS DHS to 0 C C
+ / - 0.23 DHS DHS from 0 to 1370 DHS C C C
The Type of M
DHS C from 0.26 mm to 20 DHS DHS to 0 C C
+ / - 0.25 DHS DHS from 0 to 400 DHS C C C
+ / - 0.22 C from DHS 400 DHS to 1400 DHS C C
Type N
DHS C from 0.72 mm - 200 DHS DHS to 0 C C
+ / - 0.28 DHS DHS from 0 to 1300 DHS C C C
The Type R
DHS C from 1.09 mm to 20 DHS DHS to 0 C C
+ / - 0.97 DHS DHS from 0 to 500 DHS C C C
+ / - 0.49 C from DHS 500 DHS to 1750 DHS C C
The Type of S
DHS C from 1.05 mm to 20 DHS DHS to 0 C C
+ / - 0.95 DHS DHS from 0 to 500 DHS C C C
+ / - 0.56 C from DHS 500 DHS to 1750 DHS C C
The Type T
DHS C from 0.60 mm - 200 DHS DHS to 0 C C
+ / - 0.25 DHS DHS from 0 to 400 DHS C C C
The Type of U
DHS C from 0.54 mm - 200 DHS DHS to 0 C C
+ / - 0.24 DHS DHS from 0 to 400 DHS C C C
Note 1:
Accuracies are on internal Reference Junction Compensation. Refer to the Technical manual for equivalent Accuracies with an external Reference Junction.
1523/24 Accuracies with selected the probes (plus or minus ° C)
- 200 ° C
5616-12, 0.014
5615-6:0.025
5627 - a - 12, 0.027
5610-9: n/a
0 ° c.
5616-12, 0.021
5615-6:0.021
5627 - a - 12, 0.049
5610-9, 0.009
100 ° c.
5616-12, 0.027
5615-6:0.028
5627 - a - 12, 0.065
5610-9, 0.009
300 ° c.
5616-12, 0.040
5615-6:0.043
5627 - a - 12, 0.103
5610-9: n/a
420 ° c.
5616-12, 0.050
5615-6: n/a
5627 - a - 12, 0.130
5610-9: n/a
Note 2:
Includes readout accuracy, the probe calibration, and the probe drift
PRT equivalent temperature accuracy (readout only)
- 100 ° C
+ / - 0.011
0 ° c.
+ / - 0.015
100 ° c.
+ / - 0.019
200 ° c.
+ / - 0.023
400 ° c.
+ / - 0.031
600 ° c.
+ / - 0.039
Thermistor equivalent temperature accuracy (readout only)
0 ° c.
+ / - 0.002
25 ° c.
+ / - 0.003
50 ° c.
+ / - 0.006
75 ° c.
+ / - 0.014
100 ° c.
+ / - 0.030

Mode雷竞技appl: Fluke 1524 reference thermometer

雷竞技appFluke 1523

Thermometer Readout, Handheld, 1 Channel

buy
雷竞技appFluke 1523 - P2

1523 Bundled with 5628 PRT (- 200 ° C to 660 ° C, 25 ohm (1/4 x 12 inch)), the Universal TC INFO - CON Connector, TPAK, and Case

buy

Includes:

  • The Universal TC INFO - CON Connector
  • TPAK
  • Case
雷竞技appFluke 1523 - P3
雷竞技appFluke Calibration 1523 - P3 Handheld Thermometer Readout
Bundled with 5627 a PRT (200 ° C to 420 ° C and 100 ohm (12 x 1/4 inch))
buy

Includes:

  • The Universal TC INFO - CON Connector
  • TPAK
  • Case
雷竞技appFluke 1523 - P1

1523 Bundled with 5616 PRT (200 ° C to 420 ° C and 100 ohm (1/4 x 12 inch)), the Universal TC INFO - CON Connector, TPAK, and Case

buy

Includes:

  • The Universal TC INFO - CON Connector
  • TPAK
  • Case